EasyManua.ls Logo

Miele PG 8504 - Cancel with Fault Code

Miele PG 8504
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Problem solving guide
103
Cancel with fault code
If a programme is cancelled and a fault code appears, e.g. Fault XXX (where XXX
represents a number), there could be a serious technical fault.
In the event of a programme being cancelled and a fault code being shown:
Switch the machine off using the button.
Wait approximately 10 seconds before switching the machine on again with the
button.
Start the previously selected programme again.
If the same message appears again:
Make a note of the fault message.
Switch the machine off using the button.
Contact Miele Service.
Please also read the notes regarding the following fault codes.
Problem Cause and remedy
Fault 403-405 A programme has been cancelled because water intake by
the machine was insufficient or severely restricted.
Open the stopcocks fully.
Follow the additional information given in the Check
water inlet message.
Fault 406–408 A programme was cancelled because the water flow rate is
insufficient.
Check whether the stopcocks are fully opened.
Please refer to the information regarding minimum flow
pressure in “Connection to the water supply” and
“Technical data”.
Check the filters in the water supply.
In this instance, please contact the Miele Customer
Service Department for advice.
Fault 412–414 A programme was cancelled because the water flow rate is
too high.
Refer to the information regarding recommended
maximum flow pressure and maximum permissible static
water pressure in “Connection to the water supply” and
“Technical data”.
In this instance, please contact the Miele Customer
Service Department for advice.
Fault440 The float switch in the base of the machine has not been
activated. The switch might be blocked.
Remove the filter combination.
Check the float switch to make sure it moves freely. The
float switch is located in the base of the machine behind
the spray arm.

Table of Contents