Cleaning the drain pump and non-return valve
If water was not pumped away at the end of a program, there may be
a foreign object in the drain pump or blocking the non-return valve.
Take the filter combination out of the wash chamber (see Mainte-
nance/Cleaning the filters in the wash chamber").
Open the locking clamp.
Lift out the non-return valve and rinse well under running water.
Make sure that the vent on the outside of the non-return valve is not
blocked (this vent is only visible after the non-return valve has been
taken out). If it is blocked, use a pointed object to release the block-
age.
The drain pump impeller is situated under the non-return valve (see
arrow).
Check the impeller for blockages and remove them if necessary.
Carefully replace the non-return valve and secure it with the clamp.