EasyManua.ls Logo

Miele PG 8593 - Set wash block temperature

Miele PG 8593
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programme settings
112
Set
wash block
temperature
The wash block temperature is reached by heating up the wash
water. The temperature must be suited to the requirements of the
task.
At temperatures over 55°C, protein denaturing occurs which can
cause the soiling to fix.
Infection prevention requirements must be observed as
appropriate.
...
Wash block temperature
Wash block temp.
Set
Without heater
- Without heater
The wash water is not heated up. The temperature in the wash
cabinet is the result of the temperature of the previous wash block
and the influx of water.
- Set
Setting a wash block temperature.
Select an option using the and arrow buttons.
Press OK to save the setting.
When Set is selected the wash block temperature must then be
entered.
Wash block temp.
60
(30 - 93
°C
°C)
Adjustment is in increments of 1. The possible range is shown in the
bottom line.
Dispensing of chemical agents occurs at a default dispensing
temperature set at the factory. If chemical agents are to be dispensed
in this wash block, the lowest temperature that can be set will be the
dispensing temperature. It is not possible to set a lower value.
Use the arrow buttons (higher) and (lower) to set the wash
block temperature.
Press OK to save the setting.