Technical Information
28
PW 6xx7
Item number in table Item description Options Details
16 Lock Yes / No
This setting in the program
header determines whether
the program will be locked
when it is in operation. If it is
locked, then one minute after
the program has been
started the operator cannot
stop or interrupt it with the
Finish button and the door
can only be opened when
the program has finished.
Default factory setting: No.
17 Peak load Yes / No
Peak-load cut-out: High load
peaks in electrical systems
can result in particularly high
energy costs. With major
installations, the peak-load
cut-out feature avoids these
extra charges for load peaks.
A monitoring system
registers current
consumption and when this
is too high, a cut-out signal is
produced. Machine
response: The heating is
switched off and the program
may possibly be interrupted.
When the monitoring system
resets the signal, the wash
program continues
automatically. This setting in
the program header
determines whether the
heating will be switched off
or not by a peak-load signal
being received at the Peak
load input. Default factory
setting: Yes. If the control
registers that the header of
the program in operation
permits peak-load cut-out
and the program is currently
in a heating stage when a
peak-load signal is received,
then the heating is switched
off, the program is stopped
and the display shows Prog.
stopped. Peak load cut-
out. Program will start
again automatically. The
control also corrects the
program finish time. If a
heating stage is not
operating, no message is
displayed. The peak-load
cut-out does not have an
overriding time control.