Technical Information
58
PW 6xx7
MDU fault # Possible cause Notes Indication in EW 235
display
Fault/Information
F4166 Fault - Weighing
system during
program sequence
During a wash program,
a fault has been detected in the
loading module (weighing
system). Check the plug
connection between EB 230
plug 65X and ELP 235 plug
N1L_ST22.
”Data fault. Limited
function. Loading
module defective.”
Fault
F4167 Fault - Power
interruption
ELP 235 has registered power
break ≥ 100 ms.
“Voltage interruption!
Program stop. Press
the start button.”
Fault
F4168 FEHLER_CHIPKART
E_SLT
EW 235 has registered that chip
card is inserted but ELP 235
cannot create connection.
“Card fault. Card
inserted incorrectly in
card reader.”
Fault
F4169 FEHLER_CHIPKART
E_BAE
EW 235 has registered that chip
card is inserted but EW 235
cannot create connection.
“Card fault. Card
inserted incorrectly in
card reader.”
Fault
F4170 After ID 2286: Internal
fault control with data
backup of service
settings.
After ID 2286: FEHLER_
BACKUP_SERVICEEINSTELL
UNGEN. Checksum to monitor
data backup of service settings
is incorrect.
After ID 2286: “Data
fault! Call the service
department if restart
does not work.”
Fault
F4171 After ID 2286: Internal
fault control with data
backup of list of
input/output
allocations.
Internal fault control. After ID
2286: FEHLER_ BACKUP_
EA_ZUORDNUNG. Checksum
to monitor data backup of list of
input/output allocations is
incorrect.
After ID 2286: “Data
fault! Call the service
department if restart
does not work.”
Fault
F4172 After ID 2286: Internal
fault control with data
backup of list of
system components.
Internal fault control. After ID
2286: FEHLER_
BACKUP_SYSTEMKOMPONE
NTEN. Checksum to monitor
data backup of list of system
components is incorrect.
After ID 2286: “Data
fault! Call service
department if restart
does not work.”
Fault
F4173 FEHLER_PROGRAM
MLISTE
Internal fault control. Fault in list
of programs.
Fault
F4174 Internal fault Internal fault control. Fault
F4175 FEHLER_INTERRUP
T
Internal fault control. No display Fault
F4176 FEHLER_TASK Internal fault control, internal
time exceeded for communica-
tion between ELP 235 & EW
235.
Fault
F4177 Internal fault Internal fault control EW 235. “Data fault! Call service
dept. if restart does not
work.”
Fault
F4178 Internal fault Internal fault control EW 235. No display Fault
F4179 Internal fault Internal fault control EW 235. “Data fault! Call service
dept. if restart does not
work.”
Fault
F4180 Internal fault Internal fault control EW 235. “Data fault! Call service
dept. if restart does not
work.”
Fault
F4181 Internal fault Internal fault control EW 235. “Data fault! Call service
dept. if restart does not
work.”
Fault
F4182 Internal fault Internal fault control EW 235. “Data fault! Call service
dept. if restart does not
work.”
Fault
F4186 Fault - Flash card
copying
Fault when copying data flash
card to ELP 235.
“Copying fault! Memory
card could not be
copied.”
Fault
F4187 Internal fault Internal fault control. “Data fault! Call service
dept. if restart does not
work.”
Fault