Technical Information
67
PW 6xx7
Item # in
Table
Item Description Options Details
9 Name Area 3
All available
alphanumeric and
special characters
Allocation of name for area 3. Default
setting: Rinses. Max. name length 20
characters, e.g., Final rinse cold.
10 Weigh
No
It is not possible to enter a weight before
program start. Control operates with
rated load for the machine; see Table
100-7. Default setting: No.
Manual
Operator weighs dry laundry then enters
established weight manually in machine
before program start.
Automatic
Using load module, the weight of the load
can be entered automatically in the
machine control before program start.
11
Max. load
0.0 kg, 0.2 kg, 0.4
kg, 0.6 kg, ... 32 kg
in 0.2-kg steps
Coding plug for setting the model
automatically limits the possible entry to
suit the model in question. The rated load
entry can be used as a guide for a
reduced load quantity, e.g., 3.5 kg for
Minimum iron; see Table 100-7. Default
setting: Max. value in accordance with
machine model coding plug.
12 Minimum water level
0 mm, 2 mm, 4
mm,…350 mm in
2-mm steps
Programmer sets min. water level in the
machine in mm wc (mm water column)
for all blocks without heating (heating
programming option: No). This figure sets
the lowest level that can be selected and
can be set between 0 mm to 350 mm in
2-mm steps. Default setting: 0 mm.
13 Fill type
Water height in
mm
Sets which type of monitoring is used by
control to register water level when filling
machine. Setting options available later in
wash program depend on type of fill
programmed here. Default setting: Water
height in mm, “mm” stands for
millimeters of water column (mm wc). If,
after creating a program, programmer
changes type of fill in the associated
program header from Water height in
mm to Water quantity in l or Laundry:
Suds ratio in kg/l, control modifies level
settings in the blocks accordingly. If a
change is made from Water height in
mm to Auto load adjustment, no
modifications are made in blocks. If a
setting is made that is above max.
permitted water level for machine, control
automatically limits this to permitted
maximum. If a setting is made that is
below min. permitted water level or min.
heating level for machine, control, for
safety reasons, automatically increases
this to permitted minimum in case heating
occurs during program. If control acts in
this way, it is shown at end of the
program via displays Level limitation or
Level increase.