Technical Information
75
PW 6xx7
No. Program Step Basic Options Setting Options Notes
22 Level stop 2 No
No
Water inlet takes place at same
time as Dispensing phase 2,
Agitation from level and Wash
time 2.
Yes
Water is first taken in until
programmed water level is
reached. Control interrupts
further program operation until
this has occurred and then starts
drum agitation with settings
made for Agitation from level.
Wash time 2 starts after
programmed level 2 has been
reached or after time set with
Agitation from level has
elapsed.
23 Wash time 2
Same as Wash
time 1
See Wash time 1 See Wash time 1
24 Cooldown No
No
No controlled suds cooling takes
place.
Automatic
Controlled suds cooling takes
place at 3°C/min. Valve
programmed for Intake path 2 is
opened intermittently to take in
water until max. level in machine
is reached. Drainage then takes
place down to wash level via
valves set in Drainage path 1.
Water intake and drainage are
then repeated alternately until
suds temperature has dropped to
45°C.
User-defined
Controlled suds cooling takes
place. Valve programmed for
Intake path 2 is opened
intermittently to take in water until
max. level in machine is reached.
Drainage then takes place down
to wash level via valves
programmed in Drainage path 1.
Water intake and drainage are
then repeated alternately until
selected suds temperature has
been reached. Suds temperature
can be set between 20°C and
95°C in 1°C-steps. Cooling rate
can be set between 1°C/min and
20°C/min in 1°C steps.
25 Wash time 3
Same as Wash
time 1
See Wash time 1 See Wash time 1
26 Program stop 2 No
No No stop during program
Yes
Program always stops at this
point. Program is continued by
pressing Start.