Installation
45
Dispensing-agent connection to the liquid-dispensing
mixer compartment
Connections1 and2 are provided for viscous agents. These con-
nectors are closed and must be drilled open using an 8mm bit.
Connections1 and2 can also be used for high-pressure dispens-
ing systems with water injection.
The dispensing systems must be equipped with a separate drink-
ing-water safety feature in accordance with EN61770 and
EN1717.
Care must be taken to drill through the first wall(1) only, as there is a
deflecting wall(2) 3/8" (10mm) behind it.
If the drilled-out connections are no longer required, they must be re-
sealed.
Connections3 to12 are provided for liquid dispensing. These con-
nectors are sealed and must be cut to suit the diameter of the hose
with a suitable hacksaw. If opened connectors are no longer required,
they must be capped off.