OM-261050 Page 23
SECTION 6 − ENGINE PREPARATION
6-1. Connecting the Battery
265 802-A / 287 097-B
1/2 in.
Tools Needed:
! Route battery cables
away from hot, sharp, or
moving parts.
! Connect negative (−)
cable last.
1 Battery Cable Strain
Relief
2 Starter
3 Starter Cable Lug
(Supplied)
4 Engine Block
Route cables from vehicle bat-
tery through strain relief.
Crimp supplied starter cable
lug onto positive (+) cable.
Connect positive (+) cable to
engine starter.
Locate hole in engine block
behind unit center upright.
Connect negative (−) cable to
engine block.
Battery Specification:
12 V, 650 CCA at 0° F
Battery Cable Specification:
1/0 AWG
1
1
3
2
4

Table of Contents