OM-261050 Page 26
6-4. Engine Prestart Checks
265 802-A
Check all fluids daily. Engine must be
cold and on a level surface. Unit is
shipped with 10W30 engine oil.
Follow run-in procedure in engine
manual.
This unit has a low oil pressure
shutdown switch. However, some
conditions may cause engine dam-
age before the engine shuts down.
Check oil level often and do not use
the oil pressure shutdown system
to monitor oil level.
Open top cover and service side door.
1 Oil Fill
2 Coolant Overflow Bottle
3 Radiator Cap
4 Oil Dipstick
Fuel
Be sure fuel connections are made and
tight. Be sure fuel tank utilized for unit
operation is full.
Coolant
Check coolant level in radiator and
overflow bottle. If coolant is below Low
level in overflow bottle, add coolant until
level in bottle is between Low and Full
levels. If overflow bottle coolant level
was low, check coolant level in radiator.
Engine Oil
Check oil with unit on level surface. If oil
is not up to full mark on dipstick, add oil
(see maintenance label).
Use remote panel to determine hours
until next recommended oil change
(see Section 10-2).
For cold weather starting informa-
tion, see Section 6-5.
Keep battery in good condition.
Store battery in warm area.
Use correct grade oil for cold
weather.
Continue initial system checks, see
Sections 7-4 and 8-3.