EasyManua.ls Logo

Miller Multimatic 215 - TIG Welding Connections DCEN (Direct Current Electrode Negative)

Miller Multimatic 215
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
. A complete Parts List is available at www.MillerWelds.com
OM-272989 Page 23
5-8. TIG Welding Connections DCEN (Direct Current Electrode Negative)
Ref. 275166A / Ref. 275167A / Ref. 275168A
! Turn off unit and disconnect
input power before making
connections.
1 Positive Weld Output
Receptacle
2 Negative Weld Output
Receptacle
3 TIG Torch And Cable
4 Work Clamp And Cable
Connect TIG torch cable to the
negative weld output receptacle
and connect work cable to positive
weld output receptacle.
Ensure all connections are tight.
5 Foot Control
6 Finger Tip Control
7 Remote Control Cable
8 Remote Control Receptacle
Route control cable through MIG
gun hole.
Connect foot control or finger tip
control to remote control
receptacle.
9 TIG Shielding Gas
Connection
Use Argon gas for TIG welding (see
Section 5-12).
2
1
3
4
9
5
8
6
7