SECTION 8 − MAINTENANCE & TROUBLESHOOTING
8-1. Routine Maintenance
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.
Note
Recycle engine
fluids.
Stop engine before maintaining.
See Engine Manual and Maintenance
Label for important start-up, service,
and storage information. Service unit
more often if used in severe conditions.
* To be done by Factory Authorized
Service Agent.
Every 8 h
Check Fluid
Levels. See
Section 5-6.
Wipe
Up
Spills.
OIL
Full
Coolant
Full
Every 50 h
Clean Air Filter.
See Section 8-4.
Clean And
Tighten
Weld
Terminals.
Every 100 h
Clean And
Tighten
Battery
Connections.
Check air cleaner
hoses for cracks
and loose clamps.
Every 250 h
Replace
Unreadable
Labels.
1/2 in.
(13 mm)
Check Belt
Tension.
Change Oil. See
Section 8-9.
Change Oil Filter.
See Section 8-9.
Check And
Clean Spark
Arrestor. See
Section 8-5.

Table of Contents