MT-01 HOLD MESSAGE
Field Name Definition
STX $02 ( Start Of Message )
Message Type 2 characters, 01 ( indicates the XPL+ was
removed from the RUN mode )
CR $0D ( End Of Message )
MT-03 POINT NOT SCANNED
Field Name Definition
STX $02 ( Start Of Message )
Message Type 2 characters, 03 ( indicates the Point Number
is not in service )
Point # 3 characters, 001 to 010 ( e.g. Point Number 2 )
CR $0D ( End Of Message )
If desired, the XPL+ is capable of receiving data messages from the host device, to put a vessel
"on" or "off"
priority
. ( See SMART SCAN, P720 ).
MT-12 POINT ON PRIORITY
Field Name Definition
STX $02 ( Start Of Message )
Message Type 2 characters, 12 ( put point on priority )
Point # 3 characters, 001 to 010 ( e.g. Point Number 8 )
CR $0D ( End Of Message )
MT-13 POINT OFF PRIORITY
Field Name Definition
STX $02 ( Start Of Message )
Message Type 2 characters, 13 ( take point off priority )
Point # 3 characters, 001 to 010 ( e.g. Point Number 9 )
CR $0D ( End Of Message )
End of Message
Message Type
Start of Message
e.g.
Point #
End of Message
Message Type
Start of Message
e.g.
End of Message
Message Type
Start of Message
e.g.
Point #
End of Message
Message Type
Start of Message
e.g.
Point #
PL-532 96