EasyManua.ls Logo

MIMAKI JFX-1631/1615 Plus - Irradiation Time of UV LED Unit

MIMAKI JFX-1631/1615 Plus
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-35
4
Maintenance
Irradiation Time of UV LED Unit
The UV LED is a consumable parts.
This units counts the duration of irradiation with the UV LED to notify the replacing timing.
Displaying the irradiation time of the UV LED unit
1
Press the key several times in the local mode.
The irradiation time of the left side UV LED is shown on the left and
that of the right side is shown on the right.
Press the key to return to the local mode.
Resetting the irradiation time of the UV LED unit
After replacing the UV LED Unit, reset the irradiation duration stored in this unit.
1
Select the “UV LED MODE” of the maintenance menu.
(1) Press the key in the local mode.
(2) Select the [MAINTENANCE] by pressing the or key, and press the key.
(3) Select the [UV LED] by pressing the or key.
(4) Press the key.
2
Select [LAMP TIMER] by pressing the or key.
3
Press the key.
4
Select a UV LED to be reset by pressing the or
key.
CH1, CH2, CH3, CH4, ALL(Reset irradiation duration of both UV
leds)
5
Press the key twice.
Reset irradiation duration.
A message shown in the right is displayed when resetting is
completed.
6
Press the key several times to end the setting.
ENTER