Maintaining the Capping Station
4-13
1
1
1
4
Routine Maintenance
5
Press the key.
6
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill the cap with the cleaning solution just before the
solution overflows from the cap.
7
Close the front cover and press the key.
8
Press to set the time for the cleaning
solution to be left as it is.
• Set Value : 1 to 99 min (by the unit of 1 min)
9
Press the key.
• The nozzles are washed.
• When the nozzles have been completely washed, the head moves
onto the platen.
10
Open the front cover.
11
Fill up the cap with cleaning solution for
maintenance, using a syringe.
• Fill the cap with the cleaning solution just before the
solution overflows from the cap.
12
Close the front cover and press the key.
• After its initial operation, the machine returns to LOCAL.
• Until washing liquid is filled, [COMPLETED (NEXT): ent] is displayed on the screen. After
the work up to the Step 6 is completed and you close the front cover, press the
key. If you press the key before washing liquid is filled, the carriage returns to
the original position.