Specifications
Machine specifications
Item UJF-3042MkII/3042MkII e
UJF-3042MkII EX/3042MkII EX e
UJF-6042MkII/UJF-6042MkII e
Print head
Method Drop-on-demand piezoelectric print heads
Specification 3 head, 6 nozzles 4 head, 8 nozzles
Resolution
x-dpi: 600, 900, 1200
y-dpi: 600, 1200
Drawing
mode
600 x 600 8, 10 pass
600 x 900 12, 16 pass
1200x1200 12, 16 pass
Usable inks Exclusive UV curing ink (Genuine ink)
Ink supply 6 bottles
8 bottles
Usable media
Size 300 x 420mm (11.8 x 16.5 in)
610 x 420mm (24.0 x 16.5 in)
Thickness
(1) + (2) = 153 mm or less
(1) Movable area 53 mm (2.09 in)
(2) 50 mm
(1.97 in) spacer × 2 levels = 100 mm (3.94 in)
Weight 5kg or less (11.0 lb or less)
8kg or less
(17.6 lb or less)
Max. printing area 300 x 420mm (11.8 x 16.5 in)
610 x 420mm
(24.0 x 16.5 in)
Distance
accuracy
Absolute accuracy Whichever the larger one of ± 0.3 mm(± 0.01 in) or ± 0.3 % of the designated
Reproducibility Whichever the larger one of ± 0.2 mm(± 0.008 in) or ± 0.1 % of the designated
Perpendicularity ± 0.3 mm / 400mm (± 0.01 in / 15.7 in)
Print gap adjustment Table up / down mechanism by key
Head anticollision device Head anticollision by obstacle sensor
UV unit Air-cooling LED UV device x 1 (equipped with the head slider)
Waste ink tank Bottle type ( 1600 cc)
Interface
USB 2.0 (Ethernet 10 BASE/ 100 BASE/ 1000 BASE E-mail function, only “1000
BASE” connection is applicable for drawing.)
Command MRL- V
Noise
during standby Less than 55 dB (A) (FAST-A, Front & Rear & Left & Right 1 m)
during continuous
printing
Less than 70 dB (A)
Safety Standard
VCCI Class A, FCC Class A, IEC 62368-1 ETL compliance, CE marking (EMC Direc-
tive, Low Voltage Directive, Machinery Directive), CB certified, RoHS, REACH,
EnergyStar, EAC marking, RCM marking
Power Single phase AC100 - 240 V ±10% 50 / 60 Hz ± 1 Hz
Power consumption 1000 W or less
Recomended
Environment
Available temp. 20 °C to 30 °C ( 68 °F to 86 °F )
Humidity 35 to 65% Rh (No condensation)
Guaranteed temp. 20 °C to 25 °C ( 68 °F to 77 °F )
Temperature
change
± 10 °C / h or less ( ± 50 °F / h or less )
Dust Equivalent to normal office level
Highest operation
height
2000 m ( 78.7 in )
Weight
*1
*1. Figures in the () include the dedicated stand.
150 kg (185 kg)
(330.7 lb (407.9 lb))
165kg(200kg)
(363.8lb(440.9lb))
Outside
dimensions
Width 1355 mm ( 53.3 in ) 1665 mm ( 65.6 in )
Depth 1290 mm ( 50.8 in )
Height 856 mm ( 33.7 in ) (Not including the dedicated stand and the bottle.)