Chapter 4 Maintenance
4-20
2
Press to select “
MAINTENANCE
”,
and press the key.
MAINTENANCE MENU will be displayed.
3
Press , and press the key.
Carriage will move to the left end of this machine.
4
Press the key.
“STATION” will be selecte
5
Open the right maintenance cover.
6
Take out the nozzle cap.
Hold the nozzle cap and pull it out.
7
Insert the new wiper.
Insert the nozzle cap so that its protrusion is in the
nozzle opening.
8
Close the maintenance cover, and press
the key.
After its initial operation, the machine returns to
LOCAL.
Insert it all the way in so that there are no gaps.
Maintenance cover
nozzle cap
protrusion
nozzle opening
No Good
OK
If the nozzle opening sinks down and is difficult to
insert, support the tube from below by hand.