Select the priority copying mode that is automatically selected when the Power Switch is turned ON
or Panel Reset key is pressed
Setting Value Description
Initial
Setting
0
Auto Paper (AP)
1 Auto Size (AS)
2Manual
1151H13BA
U-12 AP/AS/Manual Priority
Determine the optimum exposure level in the Auto Exposure mode, variable in seven steps.
Setting Value Description
Initial
Setting
46 Low (level 4)
47 Low (level 3)
48 Low (level 2)
49 Low (level 1)
50 Standard
51 High (level 1)
52 High (level 2)
When the exposure level is "Low," the greater level number is, the lower the exposure level.
When the exposure level is "High," the greater level number is, the higher the exposure level.
1151H14OBA
U-13 Default Auto Exposure Level
Determine the default exposure mode, either Auto or Manual, selected when the Power Switch is
turned ON or Panel Reset key is pressed.
If Auto is selected, this function also allows you to set the default exposure level in the Manual
Exposure mode, variable in 9 steps, after the Auto Exposure mode has been canceled.
If Manual is selected, the function also allows you to set the default exposure level in the Manual
Exposure mode.
Auto Exposure Mode as Default
Setting
Value
Description
Initial
Setting
Default Mode Exposure Setting in Manual Mode
0Auto Manual EXP1
1Auto Manual EXP2
2Auto Manual EXP3
3 Auto Manual EXP4
4Auto Manual EXP5
5Auto Manual EXP6
6Auto Manual EXP7
7Auto Manual EXP8
8Auto Manual EXP9
1151H15OBA
U-14 Default Exposure Mode/Level
Chapter 4
Special Functions
3. User’s Choice
54