EasyManua.ls Logo

Minolta EP4000 - Page 230

Minolta EP4000
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-6
<Clearing Procedures>
D Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ2.
4. Check that the message Initialize completed is shown on the Touch Panel, then touch “Enter.”
D Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP1 and 3.
4. Check that the message Memory Clear completed is shown on the Touch Panel, then touch “Enter.”
NOTE
D If an erratic operation or display occurs, perform the clearing procedures in the order of PJ2 and TP3.
D When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
Clearing Method
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Switch
(PJ2)
Memory Clear
Test Point
(TP3)
Misfeed display f f f f
Malfunction display (except
Exposure Lamp and fusing
system)
f f f f
Malfunction display (all includ-
ing Exposure Lamp and fusing
system)
* f f f
Erratic operation/display * * f f
User mode * * * f
Service mode * * * f
F5/F7 setting values * * * f
System Input * * * f
Accessory Test * * * f
Level History * * * f
Adjust mode * * * f
f : Cleared (initialized) *: Not cleared: