Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
M-41
1156SBM1304A
13-4. Doctor Blade
The Doctor Blade installed over the Sleeve/Magnet Roller regulates the height of the
developer brush on the surface of the Sleeve Roller. The Blade is perpendicular to the
direction of movement of the Magnet Roller to minimize variations in the distance
between the Doctor Blade and Magnet Roller as the Magnet Roller moves.
Doctor Blade
Direction of Magnet
Roller Movement
Magnet Roller
1156M017AA