Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-5
1151SBS0300A
FUNCTIONS OF SWITCHES AND POINTS ON PWB-I
3
1151SBS0301A
3-1. PWB-I Location
1156S001AA
1156SBS0302A
3-2. Tech. Rep. Settings Switches Board PWB-I
1149S002BB
Symbol Name Description
S1
Trouble Reset Switch Resets a malfunction including those of the Exposure
Lamp (C04XX) and fusing (C05xx).
PJ2
Initialize Switch Forcibly resets a misfeed or malfunction that occurrs
due to incorrect operation, etc. when it cannot be reset
by opening and closing the Front Door or the press of
S1.
TP1 GND Test Point Ground terminal used for memory clear.
TP3
Memory Clear Test Point Initializes all data except the counts of electronic count-
ers, access numbers and administrator number for Copy
Track, and RD mode functions.