Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
M-36
1156SBM1205A
12-5. Original Size Detection Timing
Master CPU on PWB-A affirms and resets the readings of the original size at the fol-
lowing timings.
D Takes size readings: When the Original Cover is raised to an angle of 15° or more
(PC111 is deactivated).
D Affirms size readings: When the Original Cover is lowered to an angle of 15° or less
(PC111 is just activated); or, when the Start key is pressed with PC111 in the deacti-
vated state.
D Resets size readings: When the Original Cover is raised (S108 is deactuated).
Magnet
Size Reset
Switch S108
Original Cover Detecting
Sensor PC111
Control Signal Blocked Unblocked WIRING DIAGRAM
PC111 PWB-A PJ17A-11 L H 21-G
Control Signal ON OFF WIRING DIAGRAM
S108 PWB-A PJ12A-1 L H 16-B