Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
M-10
1156SBM0600A
MALFUNCTION BYPASS FUNCTION6
D When a malfunction occurs in the copier, the malfunction bypass function permits
the copier to continue operating if that malfunction is one of the predefined
candidates for an isolated malfunction and if it will not affect the current copying
operation. But, if an isolated malfunction occurs anytime during the actual copy
cycle, the copier considers it a normal malfunction.
D If a copying function involving an isolated malfunction is selected, the message
Selected mode cant be used. appears on the Touch Panel and the copier rejects
that function.
D When an isolated malfunction occurs, a tiny wrench
indicator appears in the
lower left corner of the Basic Screen. Access the Machine Status display by
touching the wrench icon or via the Tech. Rep. mode to ascertain the trouble code.
Then refer to the Troubleshooting Manual for details.
D Trouble codes for up to five isolated malfunctions are shown on the “Machine
Status” display. When a sixth isolated malfunction occurs, the copier considers it
a normal malfunction, prompting a Tech. Rep. call. (The sixth malfunction is shown
on the Touch Panel.) But, if all of the paper feed ports (except the manual feed port)
show an isolated malfunction, the copier considers them a normal malfunction even
though the isolated malfunction count may be less than five. The display also tells
the condition when the image stabilization controls are not properly working.
D For the details of the Isolated malfunction codes, see TROUBLESHOOTING for the
copier and the specific SERVICE MANUAL for the options.

Table of Contents

Other manuals for Minolta EP4000

Related product manuals