Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
T-3
<Controlled Part Check Procedure by Changing Input Port Data>
Example: When a paper misfeed occurs in the paper take-up section of the copier, 1st Drawer Pa-
per Take-Up Sensor PC56 is considered to be responsible for it.
<Procedure>
1) Remove the sheet of paper misfed and reset the misfeed.
2) From the I/O port check list, it is found that the H/L input signal to PC56 is supplied from PWB-A
(IC3A) APB3.
3) Select “IC Port Check from the I/O Check function in the Tech. Rep. mode and access the
screen which includes the input ports of PWB-A (IC3A) APB3.
4) Check that the input port data of PWB-A (IC3A) APB3 on the screen is “H” (sensor being un-
blocked).
5) Move the PC56 actuator to block the sensor.
6) Return to the I/O Check basic screen once, select IC Port Check again, choose the screen
which includes the APB3 input port data, and make sure that the data has changed from “H”
to “L”.
L: PC56 is operational. H: PC56 is faulty.