2.26 Use a suitable screwdriver to tighten
the two screws through the body. The
screws will hold the shower control in
position.
2.27 Install the hot and cold supply pipes
35 mm from the finished wall at
153 mm centres.
Use the installation template to make
sure the pipes are in the right position.
2.28 Refer to section: 'Reversed Inlet
Connections' and follow instructions
8.2. to 8.10. This will put the cartridge
assembly, the indicator trim and the
temperature knob in the correct
orientation for hot left and cold right
inlet supplies.
2.29 Follow the installation instructions
2.12. to 2.15. inclusive.
2.30 Refer to Commissioning for details on
the flow regulator installation.
2.31 Turn on the water supplies and check
for any leaks.
2.32 Refer to section: 'Commissioning
and Control Assembly Installation'.
Shower Fittings.
2.33 Install the shower fittings. Refer to the
Installation and User Guide for the
shower fittings.
Compression Nut
Olive
Installation
Template
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk