Adjusting Maximum Temperature Stop
1.4 To adjust the maximum temperature position remove the lever.
Remove the red maximum stop ring by pulling on two red upstands
(Use pliers if necessary)
Standard Inlets
Pull the white maximum temperature stop apart from the red maximum lever
stop (Use pliers if necessary). Turn the white gear 1 or 2 gear teeth clockwise to
increase the maximum shower temperature or anticlockwise to decrease.
(Note! One gear tooth movement will increase or decrease the temperature by
approximately 2 °C) push together firmly.
Fit the red maximum temperature stop as described in 9.2.
- ° C
+ ° C
Missing Teeth
- ° C
+ ° C
Missing Teeth
Rear View of MaximumTemperature Stop Assembly
Reversed Inlets
Pull the white maximum temperature stop apart from the red maximum lever
stop (Use pliers if necessary). Turn the white gear 1 or 2 gear teeth anticlockwise
to increase the maximum shower temperature or clockwise to decrease.
(Note! One gear tooth movement will increase or decrease the temperature by
approximately 2 °C) push together firmly.
Fit the red maximum temperature stop as described in 9.2.
Rear View of MaximumTemperature Stop Assembly
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk