EasyManua.ls Logo

Mira COMBIFLOW - Commissioning and Control Assembly Installation; Flow Regulator Installation and Filter Access

Mira COMBIFLOW
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
Flow Regulator Installation and Filter Access
For most combination boiler and instantaneous water heater installations an 8 l/min
flow regulator (supplied fitted) is required in the hot supply of the shower mixer control.
This is to ensure a regular flow and thus a stable temperature.
Note! For other high pressure systems removal of the 8 l/min flow regulator (supplied
fitted) is recommended.
The flow regulator is fitted into the inlet filter housing as illustrated below.
Note! Make sure the flow regulator is fitted in the correct orientation either for the
Combiflow exposed or built-in (refer to illustrations below).
To access filters or the flow regulator once the shower has been installed, remove the
cover shroud (Combiflow exposed) or the concealing plate (Combiflow Built In).
Make sure that the 8 l/min white flow regulator is fitted for combination boiler and
instantaneous water heater systems.
Remove the flow regulator for high pressure and pumped systems.
Hot Inlet
Hot Inlet
Filter Housing
Filter Housing
Flow Regulator
Flow regulator
Inlet Strainer Filter
Inlet Strainer Filter
COMMISSIONING AND CONTROL ASSEMBLY INSTALLATION
Exposed Built-in
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk