RemedyMalfunction Cause A B C
Refer to 'Wide
temperature
fluctuations'.
Wait for hot water to
reheat.
Renew the cartridge.
Refer to section:
'Maintenance,
Cartridge Renewal'.
Renew ‘O’ seals with
Service Pack.
(a) Insufficient flow
rate.
(b) Hot water supply
temperature
dropped.
(a) Ceramic flow
cartridge damaged.
(b) ‘O’ seals damaged.
Shower starts
warm and then
runs cool.
Shower control
cannot be shut
off.
No flow or low
flow from shower
head.
(a) Supply stop valve
turned down or off.
(b) Inlet Strainers
blocked.
(c) Hose or handset
blocked.
Open valve.
Clean or renew the inlet
strainers.
Clear the blockage. If
necessary renew the
hose or handset.
(d) Spray plate
blocked.
Remove and clean.