Mirion Technologies RDS-31 S - Show and Change Dose Rate Alarm Level (FX.RAL;SQ.RAL)

Mirion Technologies RDS-31 S
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
To change the chirp state:
While the current chirp state is displayed, press [
]shortly
and the display shows the state of the related Chirp
function blinking
Scroll with short [Ξ] until the desired value (CA:OFF|
CA:ON; CV:OFF| CV:ON; CH:/1|…CH:/50) is given
Press an intermediate [
] (Short [
] takes back to the
menu).
The Chirp state is now set.
DivisorSubmenu
...
↓ ↑
CH:
/50
↓ ↑
/1
↓ ↑
/2→
ChooseOption
↓ ↑
/5
↓ ↑
/10
↓ ↑
/20
↓ ↑
...
The display provides the new setting without blinking and if no
button action takes place within the time-out period, the display
returns to the dose rate.
5.4.4 Show and Change Dose Rate Alarm Level
(FX.RAL/SQ.RAL)
The dose rate alarm of RDS-31 can operate in two different
modes:
Fixed dose rate alarm level
Sequential dose rate alarm
AudioSubmenu VisualSubmenu
CA:
...
CV:
...
↓ ↑ ↓ ↑
ON→
ChooseOption
OFF→
ChooseOption
↓ ↑ ↓ ↑
OFF ON
↓ ↓
... ...