6Set up Robot's Maintenance
How to Operate Maintenance 6-52
(3) Completion status
The values below are established as completion status:
(4) Data description
[Function No]
Selects the target function.
[Mecha No]
Select the target mecha. Specify a mecha in the range of mechas 1 - 3.
Setting
Value
Description
1 Successfully completed
2
Specified "Function number" and "Mecha number" are out of range (including the case that the target mecha
does not exist).
3 (Not used)
4 No target function (the function specified by target mecha does not exist)
10 NG because of a factor other than 2 to 4