EasyManua.ls Logo

Mitsubishi Electric MELFA BFP-A8787-F - Operation Command Is Impracticable

Mitsubishi Electric MELFA BFP-A8787-F
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8Perform Sequencer Direct
How to Operate Sequencer Direct 2-82
(2) Operation Command Is Impracticable:
When the command data instructed by the sequencer is not formal or when the robot is out of work, the
robot stores a number indicating an impracticable reason in "Completion status" against "Command
request" from the sequencer and then returns "Command completed".
(1) The sequencer sets up "Command data" and "Condition data" and sends "Command request ON."
(2) When "Command request ON from OFF" is received, the robot imports "Command data" and "Condi-
tion data." When the imported data is not official or when the robot is impracticable of sequencer
direct, the robot sets "Command data" (returned data) and "Completion status" to other than one,
and sends "Command completed ON."
(3) When the sequencer receives "Command completed ON", the sequencer imports "Completion sta-
tus" and sends "Command request OFF".
(4) When the robot receives "Command request OFF", the robot clears "Completion status" and "Com-
mand data" and sends "Command completed OFF".
(1) (2) (3) (4)
1, 100, 0
Sequencer
Robot
Command
completed
Robot operation
Command running
Command
condition data
Override, acceleration, deceleration, speed, ...
Command data
- Command No
- Command data 1
- Command data 2
Command request
1, 100, 0
Completion status
Other than 1
Command data
- Command No
- Command data 1
- Command data 2

Table of Contents

Related product manuals