132
4 ADVANCED SYNCHRONOUS CONTROL
4.7 Synchronous Control Monitor Data
4.7 Synchronous Control Monitor Data
Synchronous control monitor data is updated only during synchronous control.
The monitor values ([Md.400], [Md.401], [Md.402], [Md.407], [Md.408], and [Md.409]) from the last synchronous control
session are restored the next time the system's power supply turns ON. Restarting operation status from the last synchronous
control session is possible through returning to the last position via positioning control (Page 139 ADVANCED
SYNCHRONOUS CONTROL INITIAL POSITION).
"The last synchronous control session" indicates status just before the last synchronous control session was stopped as
follows. These are listed with the last synchronization status.
Just before "[Cd.380] Synchronous control start" turns from ON to OFF
Just before deceleration stop by a stop command or an error, etc.
Just before the power supply of the Motion module turns OFF
n: Axis No. - 1
Monitor item Storage details Monitor value Buffer memory address
Axis 1 to axis 16
[Md.400]
Position value after
composite main shaft gear
The current value after combining the main input and
sub input values from the main shaft is stored.
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
-2147483648 to 2147483647
[Main input axis position units
*1
]
42800+40n
42801+40n
[Md.401]
Position value per cycle after
main shaft gear
The position value per cycle after the main shaft gear
is stored.
One cycle is considered the cam axis length per cycle.
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
0 to (Cam axis length per cycle - 1)
[Cam axis cycle units
*2
]
42802+40n
42803+40n
[Md.402]
Position value per cycle after
auxiliary shaft gear
The position value per cycle after the auxiliary shaft
gear is stored.
One cycle is considered the cam axis length per cycle.
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
0 to (Cam axis length per cycle - 1)
[Cam axis cycle units
*2
]
42804+40n
42805+40n
[Md.406]
Cam axis phase
compensation amount
The current phase compensation amount is stored.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
-2147483648 to 2147483647
[Cam axis cycle units
*2
]
42810+40n
42811+40n
[Md.407]
Cam axis position value per
cycle
The position value per cycle is stored, which is
calculated from the input movement amount to the
cam axis. (The value after phase compensation)
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
0 to (Cam axis length per cycle - 1)
[Cam axis cycle units
*2
]
42812+40n
42813+40n
[Md.408]
Cam reference position
The command position value as the cam reference
position is stored.
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
-2147483648 to 2147483647
[Output axis position units
*3
]
42814+40n
42815+40n
[Md.409]
Cam axis command position
value]
The command position value while controlling the cam
axis is stored.
Value is stored even after system's power supply OFF.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
-2147483648 to 2147483647
[Output axis position units
*3
]
42816+40n
42817+40n
[Md.410]
Execute cam No.
The executing cam No. is stored.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
0 to 256
42818+40n
[Md.411]
Execute cam stroke amount
The executing cam stroke amount is stored.
Refresh cycle: Operation cycle (During synchronous
control only)
Monitoring is carried out in
decimal display.
-2147483648 to 2147483647
[Output axis position units
*3
]
42820+40n
42821+40n