2 INPUT AXIS MODULE
2.2 Command Generation Axis
39
2
Command generation axis parameters
All command generation axis parameters are prepared for each command generation axis. However, change the parameters
using GX Works3 or control data because the parameters are not in the buffer memory.
*1 Command generation axis position units (Page 38 Command generation axis position units)
[Pr.340] Command generation axis valid setting
Set valid/invalid of the command generation axis.
[Pr.346] Command generation axis length per cycle
Set the length per cycle for the command generation axis position value per cycle.
The current value of command generation axis is stored in "[Md.347] Command generation axis position value per cycle" at
ring counter based on the setting value.
The unit settings are in command generation axis position units (Page 38 Command generation axis position units).
Set a value within the range from 1 to 2147483647. If a value out of the range is input, "Outside command generation axis
length per cycle setting error" (error code: 1DFDH) occurs and the axis operates as that the length per cycle is 0.
If "0" is set, "[Md.347] Command generation axis position value per cycle" is not updated.
Setting item Setting details Setting value Default value Buffer memory
address
[Pr.340]
Command generation axis valid
setting
Set valid/invalid of the command
generation axis to be used.
Fetch cycle: Power supply ON
Set in decimal.
0: Invalid
1: Valid
0
[Pr.346]
Command generation axis length per
cycle
Set the length per cycle of the
command generation axis.
Fetch cycle: Power supply ON
Set in decimal.
0: Invalid
1 to 2147483647
[Command generation axis position
units
*1
]
0
Setting value Details
0: Invalid Command generation axis is invalid.
1: Valid Command generation axis is valid.

Table of Contents