76
3 CAM FUNCTION
3.1 Control Details for Cam Function
Cam data
The cam data used in the cam function includes "storage data" which is used for reading/writing with the engineering tool and
"open data" which is transmitted to the internal memory at cam control.
Storage data and open data are same for cams using the stroke ratio data format and the coordinate data format. A cam using
the auto-generation data format (storage data) operates after being changed (transmitted) to the stroke ratio data format.
Linear cam control
When "0" is set for "[Pr.440] Cam No.", the cam data operates as a straight line with a 100% stroke ratio at the last point.
The linear cam does not consume the cam open area. Also, it cannot be read/written as storage data.
Storage data Open data
(Reading and writing not possible) Linear cam
Stroke ratio data format Stroke ratio data format
Auto-generation data format Cam for rotary cutter
Coordinate data format Coordinate data format
t
t
Cam axis position
value per cycle
Command
position value
Cam reference
position
(At 3rd cycle)
Cam reference
position
(At 2nd cycle)
Cam reference
position
(At 1st cycle)
Stroke amount × 100%