144
6 USING THE PROGRAMMABLE CONTROLLER CPU MONITORING FUNCTION
6.3 Settings for Using the Programmable Controller CPU Monitoring Function
(0) Convert the registration command into pulse.
(3) Set the execution type.
Set the execution type (Programmable controller monitoring registration).
Set the unit of the cycle time to 'Minute'.
Set the cycle time to three minutes.
Set the monitoring function to fixed cycle send.
Set the transmission method to data transmission.
Set the output start pointer.
Set the number of the user frame to be transmitted.
Set the number of registered word blocks designation to '1'.
Set the number of registered bit blocks designation to '1'.
Register the device of D100 to D109 as the first block.
Register the device of M0 to M15 as the second block.
(43) Execute the programmable controller CPU monitoring registration.
(54) Processing for normal completion or abnormal completion