PARAMETERS
71
Func-
tion
Para-
meter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
setting
80 Motor capacity
0.1 to
7.5kW,
9999
0.01kW 9999 107
82 Motor exciting current
0 to 500A,
9999
0.01A 9999 108
83 Rated motor voltage 0 to 1000V 0.1V 200V 108
84 Rated motor frequency 50 to 120Hz 0.01Hz 60Hz 108
90
Motor constant (R1)
(Note 4)
0 to 50
Ω
,
9999
0.001
Ω
9999 108
General-purpose magnetic flux
vector control
96
Auto-tuning
setting/status (Note 4)
0, 1 1 0 108
117 Station number 0 to 31 1 0 114
118 Communication speed 48, 96, 192 1 192 114
119 Stop bit length
0, 1
(data length
8)
10, 11
(data length
7)
1 1 114
120
Parity check
presence/absence
0, 1, 2 1 2 114
121
Number of
communication retries
0 to 10,
9999
1 1 114
122
Communication check
time interval
0 to 999.8 s,
9999
0.1 s 0 114
123 Waiting time setting
0 to 150,
9999
1 9999 114
Communication functions
124
CR
⋅
LF
presence/absence
selection
0, 1, 2 1 1 114
145 Parameter for option (FR-PU04).
Additional
function
146 Parameter set by manufacturer. Do not set.
150
Output current
detection level
0 to 200% 0.1% 150% 125
151
Output current
detection period
0 to 10 s 0.1 s 0 125
152
Zero current detection
level
0 to
200.0%
0.1% 5.0% 126
Current detection
153
Zero current detection
period
0.05 to 1 s 0.01 s 0.5 s 126
Sub
function
156
Stall prevention
operation selection
0 to 31, 100 1 0 127
Parameter List
4