PARAMETERS
70
Func-
tion
Para-
meter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
setting
Display
functions
52
PU main display data
selection
0, 23, 100 1 0 93
57 Restart coasting time
0 to 5 s,
9999
0.1 s 9999 95
Automatic
restart
functions
58 Restart cushion time 0 to 60 s 0.1 s 1.0 s 95
60
Shortest acceleration/
deceleration mode
0, 1, 2,
11, 12
1096
61
Reference I for
intelligent mode
0 to 500A,
9999
0.01A 9999 96
62
Reference I for
intelligent mode
acceleration
0 to 200%,
9999
1% 9999 96
63
Reference I for
intelligent mode
deceleration
0 to 200%,
9999
1% 9999 96
65 Retry selection 0, 1, 2, 3 1 0 98
66
Stall prevention
operation level
reduction starting
frequency (Note 4)
0 to 400Hz 0.01Hz 60Hz 86
67
Number of retries at
alarm occurrence
0 to 10,
101 to 110
1098
68 Retry waiting time 0.1 to 360 s 0.1 s 1 s 98
69
Retry count display
erasure
01098
70
Special regenerative
brake duty
0 to 30% 0.1% 0% 89
71 Applied motor (Note 4)
0, 1, 3, 5, 6,
13, 15, 16,
23, 100,
101, 103,
105, 106,
113, 115,
116, 123
1 0 100
72
PWM frequency
selection
0 to 15 1 1 101
75
Reset selection/
disconnected PU
detection/PU stop
selection
0 to 3,
14 to 17
1 14 102
77
Parameter write
disable selection
0,2 1 0 104
78
Reverse rotation
prevention selection
0,1,2 1 0 105
Operation selection functions
79
Operation mode
selection (Note 4)
0 to 2 1 2 106
Parameter List