11
1.3 Functions of DIP switches
1. Outline
1.3 Functions of DIP switches
Open the door of the panel, and you can see a printed circuit board on the main body side. At the upper left
section of this printed circuit board, there are 8-pole DIP switches.
When the power is turned on, the set conditions of these switches will be read out.
Each switch has the following function:
No.1 - - - Sets the tension unit to (N) or ( ×10N ).
No.2 - - - Sets the taper control method.
No.3 - - - Sets the taper control method.
No.4 - - - Sets the function of the AO1 output.
Set tension monitor - - Outputs the target tension
value in the automatic
control mode.
Tension monitor- - - - - Outputs the material
tension value detected by
the tension detector.
No.5 - - - Sets the language to be displayed on the liquid
crystal display.
No.6 - - - (No function is assigned.)
No.7 - - - Resets data to the initial values for factoring default settings.
No.8 - - - Sets the operation mode or the adjustment mode.
Before setting the DIP switches, be sure to externally cut off the power of all the phases. If the powers
to all the phases are not cut off, you may get an electric shock, or the product may be seriously
damaged.
DIP switches
Setting for taper control method
Before changing the set position of a switch,
be sure to turn the power off.
1
2
3
4
Set tension
monitor
5
6
7
initialization
8
Operation
OFFON
SW.No
SW. No.6 is set ON and other SW are set OFF
when the product is delivered from the factory.
Unit of tension
Taper control
method
Taper control
method
AO1 output
Language
selection
Language
selection
Data
initialization
Operation
mode
Japanese
English
×10N
Tuning
No
initialization
Chinese
Tension
monitor
N
SW.No
Item
2 3
ON
OFFON
ON
ONOFF
OFF OFF
No taper control
Reel diameter
internal calculation method
External reel diameter
signal method
No taper control
Setting for language
SW.No
Language
5 6
ON OFFEnglish
OFF OFFChinese
ON ON
Japanese
OFF ON

Table of Contents