Loading...
51
12.4 External wiring diagram and terminal arrangement
12. Specifications
12.4 External wiring diagram and terminal arrangement
*1 This fuse is a specified part, and melts down only when an abnormality occurs. Users cannot replace it.
Contact Mitsubishi Electric System & Service.
+5V
RED
BLK
S G
S G
5V
PP
PN
TOUT
AO1
AOC
GRL
WHL
GRR
WHR
AI1
AI2
AIC
MIC
RUN
MI1
MI2
MI3
+
8V
N
L
adjustment
5V
+5V
AIC
Power supply for
variable resistor
Power supply for
tension detector
Shielded cable
Power supply
Grounding resistance
Tensino detector
Left
Tension detector
Right
adjustment
Photo coupler
ZT
ZT
RY
AC100 to 240
50 / 60Hz
+10%
-15%
100 or less
10K
100K
0.1
100K
1.6K
Run/stop
Zero/span
Zero/span
Metal plate
(Refer to page 5.)
Power supply fuse 250V T5AH x2 (*1)
24 VDC, 3 A or less
Powder clutch / brake
Hysteresis clutch / brake
Control output
0 to 5V
Tension monitor
/ tension set monitor output
0 to 5V
Zero tension detection signal
250V AC,0.5A
or 30V DC, 0.5A
ZTL N PP
RUN
MIC
PNZT
MI1 +5V AI1
AI2
GRL RED BLK
TOUT
GRR AO1AOC
WHRSG SGWHLAICMI2
MI3

Table of Contents