3.1 Screen System
3. Screen system and method of change screen
3. Screen system and method of change screen
3.1 Screen System
3.1.1 Overall of screen system
The screens shown on the LCD display are shown below. To change screen, use the corresponding
function key (F1 through to F4 keys) or the screen selector keys (S and T keys).
Power-on
Operation mode
(When DIP switch 8 = ON)
Adjustment mode
(When DIP switch 8 = OFF)
When memory cassette
is inserted
Parameter initialization
(When DIP switch 7 = ON)
Screen displayed
turning off the power
in the operation mode
Manual
mode key
(13)
Automatic
mode key
(12)
F1 F2 F3 F4
Tension setting
screen
Manual Setting 1
screen
Manual Setting 2
screen
Taper rate setting
screen
Tension monitoring
screen (Total)
Tension monitoring
screen (Right, Left)
Extension screen
Use the function keys
to go to the desired
screen. The functions
of F1 through F4 keys
depend on the screen.
Password input screen
(Note)
Adjustment/setting item
selection screen
• F2Auto zero
adjustment screen
• F1Input/output
monitoring screen
• F3Auto span
adjustment screen
• F4Menu copy screen
F1 F2 F3 F4
[2] Go to the desired
screen by selecting
the corresponding
item number using
the value setting dial
(16) and then
pressing the key.
[1] Go to the desired
screen using the
corresponding
function key.
Memory cassette
operation screen
Parameter initialization
screen
Operation completion
screen
Initialization
completion screen
F1 F4
After turning off the
power, remove the
memory cassette.
Then, turn on the
power.
Select the
operation
type.
Initializes the
parameter
After turning off the
power, turn off the DIP
switch 7, and turn on
DIP switch 8. After
that, turn on the power.
Execute
operation.
F1 F4
10:Stop timer,
Stop gain
11:Gain 1, gain 2
22:Manual zero
adjustment
23:Manual span
adjustment
30:Tension output
filter time constant
32:Low excitation
40:Proportional gain,
integral time
41:Additional gain,
addition dead band
width
50:Contact input of
MI1, MI2,MI3
51:Analog input of
AI1,AI2
52:Extension screen
setting
20:Full-scale tension,
Decimal point to
be indicated
21:Tension monitor
filter time constant
54:Pass word
setting screen
1:Tension setting
2:Manual Setting 1 ,2
3:Taper rate setting
Manual
mode key
(13)
Automatic
mode key
(12)
Operation mode screen
After turning off the power,
turn on DIP switch 8, and
then turn on the power.
26:Zero tension
detection
Priority order for screen selection at power-on.
(1) Memory cassette insertion screen
(2) Parameter initialization screen
(3) Adjustment mode screen
(Note) When a password setting value is
zero, a password input screen is
not displayed.

Table of Contents