17
3.2 Method of change screen
3. Screen system and method of change screen
3.2 Method of change screen
3.2.1 Initial screen displayed at power-on
The initial screen displayed just after power-on depends on the memory cassette insertion condition, ON/
OFF status of DIP switch 7, and ON/OFF status of DIP switch 8 as shown below.
(1) When the memory cassette is inserted. - - - Memory cassette operation screen
(2) When DIP switch 7 is ON. - - - - - - - - - - - - - Parameter initialization screen
(3) When DIP switch 8 is OFF. - - - - - - - - - - - - Adjustment mode screen
(4) When DIP switch 8 is ON. - - - - - - - - - - - - - Normal operation mode screen
If two or more modes are set, the following priority order will be observed to display the screen.
[1] Memory cassette operation mode
[2] Parameter initialization mode
[3] Adjustment mode
3.2.2 Functions of function key(4)
There are four function keys(F1 through to F4) for the LCD, and the functions assigned to these function
keys are displayed on the bottom line of the screen using the pictograms. Pressing a function key will
execute the corresponding function.
The functions assigned to the function keys depend on the screen currently displayed.
When DIP switch 8
= ON
When DIP switch 8
= OFF
When memory
cassette is inserted
When DIP switch 7
= ON
Adjustment/setting item
selection screen
Memory cassette
operation screen
Parameter
initialization screen
Operation mode
screen
Power-on
Password
input screen
(Note)
(Note) When a password setting value is zero,
a password input screen is not displayed.
- - - Moves to the tension setting screen.
- - - Moves to the manual setting screen.
- - - Moves to the taper setting screen.
- - - Moves to the extension screen.
- - - Moves to the tension monitoring screen or input/output monitoring screen.
- - - Moves to the auto zero adjustment screen.
- - - Moves to the auto span adjustment screen.
- - - Moves to the menu copy screen.
- - - Execute the operation command.
- - - Cancels the operation command.
- - - Set the function.
- - - Switches the selected item.

Table of Contents