12.1 Input/output specifications
12. Specifications
12. Specifications
12.1 Input/output specifications
12.2 Environmental specifications
Item
Terminal
name
Specifications
Power
supply
Input
L
• 100 to 240 VAC (-15% to +10%), 50/60 Hz • Power fuse : 250 V, T5AH ×2, built in
• Power consumption: 400 VA (at 24 VDC, 3A) • Rush current : 30A, 300ms
• Allowable instantaneous power interruption: 10 ms
N
Output
RED
• 5 VDC, power supply for tension detector
• Connect the lead wires of RED=red(+) and BLK=black (
–).
• The right and left LX-TD type tension detectors (2 detectors in total) can be connected.
BLK
+5V
• Service power supply for the external variable resistor
• 5 VDC, 50 mA or less
AIC
Contact
signals
Input
MIC • Contact input common terminal
8 VDC
4.5 mA/terminal
RUN • Run/stopON = automatic operation, OFF = stop
MI1 • Select one from the following functions
• Output memory • Output gain 1
• Output gain 2 • Output ON/OFF
• Manual output • Manual output 2
Assign the function to
each terminal using item
number 50 in the
adjustment mode.
MI2
MI3
Output
ZT
• Zero tension detection output - - - - - - - Set value : 0 to 2000 (N,×10N)
• Output becomes ON when tension does not exceed set value.
• Output is always OFF when "0" is set.
• 250V AC, 0.5A or 30VDC, 0.5A
ZT
Analog
signals
Input
GRL
Left
• Tension detector inputs. Connect the lead wires of GR=green and WH=white.
• To use the right or left side only, short the line between the GR and WH on the
unused side.
• The controller will automatically judge the load type of compression or tension.
WHL
GRR
Right
WHR
AIC • Analog input common terminal
AI1
• Select one from the following functions
• Tension setting signal • Winding diameter signal
• External tension signal • Taper rate setting signal
• Manual setting signal 1 • Manual setting signal 2
• 0 to 5 VDC voltage signal or 10kΩ variable resistor
Assign the function to each
terminal using item number
51 in the adjustment mode.
AI2
Output
AOC • Analog output common terminal
TOUT • Control output: 0 to 5 VDC / for power amplifier and AC servo amplifier
Load resistance:
1 kΩ or more
AO1
• Output for tension monitoring or tension set monitoring, 0 to 5 VDC,
• Set the function using DIP switch.
PP
• For 24VDC powder clutch/brake or hysteresis clutch/brake
• 0 to 24 VDC, 3 A or less
PN
Ambient temperature • 0 to 40ºC- - - - - during operation
Ambient humidity • 35 to 85% RH (no condensation)- - - - during operation
Vibration resistance
• 10 to 55Hz 0.5mm (4.9m/s
2
max) 2 hours in each axis direction.
Impact resistance
• 98m/s
2
3 times in each axis direction.
Noise resistance • By noise simulator with 1,000Vp-p noise voltage, 1µs noise width and 30 to 100Hz.
withstand voltage • 1,500V AC, 1 minute
Entire terminals as a whole and
between the ground terminal.
Insulation resistance • 5MΩ or more by 500V DC megger
Grounding
• Grounding registance 100Ω or less. (Grounding shall not be performed together with any
high power system.)
Operation atmosphere • Free from corrosive or flammable gas and conductive dust, less dust.