12.3 Set item list
12. Specifications
50
12.3 Set item list
(Note)
[1] The data marked with [c] in the "menu" column for the "Management of setting" column can be
stored in the menu function or read out from the menu function.
[2] The data marked with [c] in the "menu" column for the "Management of setting" column can be set in
the adjustment mode only. Setting the item in the other modes is not possible.
[3] The data marked with [×] in the "Setting during operation" column cannot be changed while the run/
stop signal [RUN] is ON. 
[4] The items marked with [c] in the "Keyin" column can be set the keyin function.
Items of setting Unit
Range of setting
Initial 
value
Management of 
setting 
Setting 
during 
operation 
Keyin
Item 
No.
Minimum Maximum Menu System
Te n sio n
Tension setting value
N,
×10N
Minimum Full-scale tension 200 c × cc1
Full-scale value
N,
×10N
1 2000 500 × c × c
20
Decimal point --- 0.01, 0.1, 1 1 × c × c
Zero point tuning      --- 0 0 0 × c ××24
Span adjustment target 
value
N,
×10N
1 to full-scale tension
(1/3 of full-scale value or more is 
needed.)
500 × c ××25
Manual zero point 
adjusting
N,
×10N
-999 +999 0 × c × c 22
Manual span adjusting % 50 300 100 × ccc23
Zero tension setting
N,
×10N
0 full-scale tension 0 c × cc26
Tension display filter time 
constant
s 0.2 to 4.0 2.0 × ccc21
Tension output filter time 
constant
s 0.2 to 4.0 2.0 × ccc30
Manual output setting 1 % 0 100 20 c × cc
2
Manual output setting 2 % 0 100 20 c × cc
Taper rate
 (internal calculation 
method)
%0 800c × cc
3
Taper rate 
(external signal method)
% 0 100 0 c × cc
Gain 1 % 5 400 100 c × cc
11
Gain 2 % 5 400 100 c × cc
Stop timer s 0.0 30.0 0.0 c × cc
10
Stop gain % 5 400 100 c × cc
Low excitation setting value % 0 50 0 × ccc31
Control gain
Proportional gain % 0 100 50 c × cc
40
Integral time % 1 100 50 c × cc
Additional gain % 0 100 0 c × cc
41
Dead band width % 0 50 50 c × cc
Selection item
MI1 contact input 
setting
---
• Output memory    • Output gain 1
• Output gain 2       • Output ON/OFF
• Manual output      • Manual output 2
Not 
set
× c × c
50
MI2 contact input 
setting
Not 
set
× c × c
MI3 contact input 
setting
Not 
set
× c × c
AI1 analog input setting
---
• Tension setting signal
• Winding diameter signal
• External tension signal
• Taper rate setting signal
• Manual setting signal 1
• Manual setting signal 2
Not 
set
× c × c
51
AI2 analog input setting
Not 
set
× c × c
Operation screen additional 
setting 1
---
10 53 0 × c ××
52
Operation screen additional 
setting 2
10 53 0 × c ××
Password setting  --- 0 30000 0 × c × c 54