6. NORMAL GAIN ADJUSTMENT 
6 -  1 
 
6. NORMAL GAIN ADJUSTMENT 
POINT 
 
In the torque control mode, you do not need to make gain adjustment. 
Before making gain adjustment, check that your machine is not being operated 
at maximum torque of the servo motor. If operated over maximum torque, the 
machine may vibrate and may operate unexpectedly. In addition, make gain 
adjustment with a safety margin considering characteristic differences of each 
machine. It is recommended that generated torque during operation be under 
90% of the maximum torque of the servo motor. 
For the vibration suppression control tuning mode, the setting range of [Pr. 
PB07] is limited. For the vibration suppression control tuning mode, the setting 
range of [Pr. PB07] is limited. Refer to section 7.1.5 (4) for details. 
 
6.1 Different adjustment methods 
6.1.1 Adjustment on a single servo amplifier 
The following table shows the gain adjustment modes that can be set on a single servo amplifier. For gain 
adjustment, first execute "Auto tuning mode 1". If you are not satisfied with the result of the adjustment, 
execute "Auto tuning mode 2" and "Manual mode" in this order. 
 
(1)  Gain adjustment mode explanation 
 
Gain adjustment mode  [Pr. PA08] setting 
Estimation of load to motor 
inertia ratio 
Automatically set 
parameters 
Manually set 
parameters 
Auto tuning mode 1 
(initial value) 
_ _ _ 1  Always estimated  GD2 ([Pr. PB06]) 
PG1 ([Pr. PB07]) 
PG2 ([Pr. PB08]) 
VG2 ([Pr. PB09]) 
VIC ([Pr. PB10]) 
RSP ([Pr. PA09]) 
Auto tuning mode 2  _ _ _ 2  Fixed to [Pr. PB06] value  PG1 ([Pr. PB07]) 
PG2 ([Pr. PB08]) 
VG2 ([Pr. PB09]) 
VIC ([Pr. PB10]) 
GD2 ([Pr. PB06]) 
RSP ([Pr. PA09]) 
Manual mode  _ _ _ 3    GD2 ([Pr. PB06]) 
PG1 ([Pr. PB07]) 
PG2 ([Pr. PB08]) 
VG2 ([Pr. PB09]) 
VIC ([Pr. PB10]) 
2 gain adjustment mode 1 
(interpolation mode) 
_ _ _ 0  Always estimated  GD2 ([Pr. PB06]) 
PG2 ([Pr. PB08]) 
VG2 ([Pr. PB09]) 
VIC ([Pr. PB10]) 
PG1 ([Pr. PB07]) 
RSP ([Pr. PA09]) 
2 gain adjustment mode 2  _ _ _ 4  Fixed to [Pr. PB06] value  PG2 ([Pr. PB08]) 
VG2 ([Pr. PB09]) 
VIC ([Pr. PB10]) 
GD2 ([Pr. PB06]) 
PG1 ([Pr. PB07]) 
RSP ([Pr. PA09])