3. SIGNALS AND WIRING 
3 -  20 
 
3.5.2 Output device 
(1)  Output device pin 
The following shows the output device pins and parameters for assigning devices. 
 
Connector pin No.  Parameter  Initial device  I/O division 
CN3-13 [Pr. PD07]  MBR 
DO-1 
CN3-9 (Note)  [Pr. PD08] 
Not assigned 
(always off) 
CN3-15 (Note)  [Pr. PD09] 
Not assigned 
(always off) 
 
Note. The CN3-9 and CN3-15 pins are available with servo amplifiers having software 
version C5 or later, and manufactured in May 2016 or later. For the servo amplifiers 
manufactured in China, these pins have been available from the June 2016 
production. 
 
(2)  Output device explanations 
 
Device  Symbol  Function and application 
Electromagnetic 
brake interlock 
MBR  When using the device, set operation delay time of the electromagnetic brake in [Pr. PC02]. 
When a servo-off status or alarm occurs, MBR will turn off. 
Malfunction  ALM  When the protective circuit is activated to shut off the base circuit, ALM will turn off. 
When an alarm does not occur, ALM will turn on after 2.5 s to 3.5 s after power-on. 
In-position  INP  When the number of droop pulses is in the in-position range, INP will turn on. The in-position range 
can be changed using [Pr. PA10]. When the in-position range is increased, INP may be on during 
low-speed rotation. 
The device cannot be used in the speed control mode, torque control mode, or continuous 
operation to torque control mode. 
Ready  RD  Enabling servo-on to make the servo amplifier ready to operate will turn on RD. 
Speed reached  SA  SA will turn off during servo-off. When the servo motor speed reaches the following range, SA will 
turn on. 
Preset speed ± ((Preset speed × 0.05) + 20) r/min 
When the preset speed is 20 r/min or slower, SA always turns on. 
The device cannot be used in the position control mode and torque control mode. 
Limiting speed  VLC  When the speed reaches the speed limit value in the torque control mode, VLC will turn on. When 
the servo is off, TLC will be turned off. 
The device cannot be used in the position control mode and speed control mode. 
Zero speed detection  ZSP  ZSP turns on when the servo motor speed is zero speed (50 r/min) or slower. Zero speed can be 
changed with [Pr. PC07]. 
OFF
ON
Servo motor
speed
20 r/min
(Hysteresis width)
[Pr. PC07]
20 r/min
(Hysteresis width)
OFF level
-70 r/min
ON level
-50 r/min
ON level
50 r/min
OFF level
70 r/min
0 r/min
[Pr. PC07]
ZSP
(Zero speed
detection)
1)
3)
2)
4)
Forward
rotation
direction
Reverse
rotation
direction
 
ZSP will turn on when the servo motor is decelerated to 50 r/min (at 1)), and will turn off when the 
servo motor is accelerated to 70 r/min again (at 2)). 
ZSP will turn on when the servo motor is decelerated again to 50 r/min (at 3)), and will turn off 
when the servo motor speed has reached -70 r/min (at 4)). 
The range from the point when the servo motor speed has reached on level, and ZSP turns on, to 
the point when it is accelerated again and has reached off level is called hysteresis width. 
Hysteresis width is 20 r/min for this servo amplifier.