6. NORMAL GAIN ADJUSTMENT 
6 -  27 
 
(2)  2 gain adjustment mode 2 
Use 2 gain adjustment mode 2 when proper gain adjustment cannot be made with 2 gain adjustment 
mode 1. Since the load to motor inertia ratio is not estimated in this mode, set the value of a proper load 
to motor inertia ratio in [Pr. PB06]. 
The following parameters are used for 2 gain adjustment mode 2. 
 
(a)  Automatically adjusted parameter 
The following parameters are automatically adjusted by auto tuning. 
 
Parameter Symbol  Name 
PB08  PG2  Position loop gain 
PB09  VG2  Speed loop gain 
PB10  VIC  Speed integral compensation 
 
(b)  Manually adjusted parameter 
The following parameters are adjustable manually. 
 
Parameter Symbol  Name 
PA09  RSP  Auto tuning response 
PB06  GD2  Load to motor inertia ratio 
PB07  PG1  Model loop gain 
 
(3)  Adjustment procedure of 2 gain adjustment mode 
 
POINT 
 
Set the same value in [Pr. PB07 Model loop gain] for the axis used in the 2 gain 
adjustment mode. 
 
Step Operation  Description 
1  Set the auto tuning mode. 
Select the auto tuning 
mode 1. 
2 
During operation, increase the response level setting value in [Pr. 
PA09], and return the setting if vibration occurs. 
Adjustment in auto tuning 
mode 1 
3 
Check value of the model loop gain and the load to motor inertia 
ratio in advance. 
Check the upper setting 
limits. 
4  Set the 2 gain adjustment mode 1 ([Pr. PA08]: _ _ _ 0). 
Select the 2 gain 
adjustment mode 1 
(interpolation mode). 
5 
When the load to motor inertia ratio is different from the design 
value, select the 2 gain adjustment mode 2 ([Pr. PA08]: _ _ _ 4) 
and then set the load to motor inertia ratio manually in [Pr. PB06]. 
Check the load to motor 
inertia ratio. 
6 
Set the model loop gain of all the axes to be interpolated to the 
same value. At that time, adjust the values to the setting value of 
the axis which has the smallest model loop gain. 
Set model loop gain. 
7 
Considering the interpolation characteristic and motor status, 
fine-adjust the model loop gain and response level setting. 
Fine adjustment