11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 46
(b) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-10B to MR-JE-100B
MCCB
Servo amplifie
r
1
2
3
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
1-phase
200 V AC to 240 V AC
123
MC
EMC filter
L1
L2
L3
4
5
6
E
Note 1. Connect the power supply to L1 and L3. Leave L2 open.
2. The example is when a surge protector is connected.
(c) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-200B
MCCB
Servo amplifie
r
1
2
3
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
1-phase
200 V AC to 240 V AC
123
MC
EMC filter
L1
L2
L3
4
5
6
E
Note 1. Connect the power supply to L1 and L2. Leave L3 open.
2. The example is when a surge protector is connected.