APPENDIX 
App. -  10 
 
App. 4.3 Electrical Installation and configuration diagram 
 
WARNING
 
Turn off the molded-case circuit breaker (MCCB) to avoid electrical shocks or 
damages to the product before starting the installation or wiring. 
 
CAUTION
 
Connecting a servo motor for different axis to U, V, W, or CN2 of the servo 
amplifier may cause a malfunction. 
Securely connect the cables in the specified method and tighten them with the 
specified torque. Otherwise, the servo motor may operate unexpectedly. 
 
The following shows representative configuration examples to conform to the IEC/EN/UL/CSA standards. 
 
(1) 3-phase input 
MCCB
or fuse
Controller
Encoder cable
(3-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
PE
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
U/V/W/PE
CN2
CN1
L2L3
To protective equipment
(Thermal signal) (Note)
 
Note. Please use a thermal sensor, etc. for thermal protection of the servo motor. 
 
(2) 1-phase input 
MCCB
or fuse
Controller
Encoder cable
(1-phase
230 V AC)
Power
supply
(3-phase
400 V AC)
Transformer
(star-connected)
PE
(Note 2)
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
U/V/W/PE
CN2
CN1
L2L3
To protective equipment
(Thermal signal) (Note 1)
 
Note   1.  Please use a thermal sensor, etc. for thermal protection of the servo motor. 
    2.  For the MR-JE-200_ servo amplifiers, connect the power supply to L1 and L2. 
Leave L3 open. 
 
The connectors described by rectangles are safely separated from the main circuits described by circles. 
Use MR-JE servo amplifiers in combination with HG series or HJ series servo motors.