3. SIGNALS AND WIRING 
3 -  1 
 
3. SIGNALS AND WIRING 
WARNING 
Any person who is involved in wiring should be fully competent to do the work. 
Before wiring, turn off the power and wait for 15 minutes or more until the charge 
lamp turns off. Otherwise, an electric shock may occur. In addition, when 
confirming whether the charge lamp is off or not, always confirm it from the front 
of the servo amplifier. 
Ground the servo amplifier and servo motor securely. 
Do not attempt to wire the servo amplifier and servo motor until they have been 
installed. Otherwise, it may cause an electric shock. 
The cables should not be damaged, stressed, loaded, or pinched. Otherwise, it 
may cause an electric shock. 
To avoid an electric shock, insulate the connections of the power supply 
terminals. 
 
CAUTION
 
Before removing the CNP1 connector from MR-JE-40B to MR-JE-100B, 
disconnect the lead wires of the regenerative resistor from the CNP1 connector. 
Wire the equipment correctly and securely. Otherwise, the servo motor may 
operate unexpectedly, resulting in injury. 
Connect cables to the correct terminals. Otherwise, a burst, damage, etc. may 
occur. 
Ensure that polarity (+/-) is correct. Otherwise, a burst, damage, etc. may occur. 
The surge absorbing diode installed to the DC relay for control output should be 
fitted in the specified direction. Otherwise, the emergency stop and other 
protective circuits may not operate. 
DOCOM
24 V DC
Servo amplifier
RA
For sink output interface
Control output
signal
 
DOCOM
Control output
signal
24 V DC
Servo amplifier
RA
For source output interface
 
Use a noise filter, etc. to minimize the influence of electromagnetic interference. 
Electromagnetic interference may be given to the electronic equipment used near 
the servo amplifier. 
Do not install a power capacitor, surge killer, or radio noise filter (optional FR-BIF) 
with the power line of the servo motor. 
When using a regenerative resistor, switch power off with the alarm signal. 
Otherwise, a transistor fault or the like may overheat the regenerative resistor, 
causing a fire. 
Do not modify the equipment. 
Connect the servo amplifier power output (U/V/W) to the servo motor power input 
(U/V/W) directly. Do not let a magnetic contactor, etc. intervene. Otherwise, it may 
cause a malfunction. 
U
Servo motor
M
V
W
U
V
W
U
M
V
W
U
V
W
Servo amplifier
Servo motorServo amplifier