EasyManua.ls Logo

Mitsubishi MR-JE-70B - Page 92

Mitsubishi MR-JE-70B
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. STARTUP
4 - 13
(b) Positioning operation
Positioning operation can be performed without using the servo system controller. Use this operation
with the forced stop reset. This operation may be used independently of whether the servo is on or
off and whether the servo system controller is connected or not.
Exercise control on the positioning operation screen of MR Configurator2.
1) Operation pattern
Item Initial value Setting range
Travel distance [pulse] 4000 0 to 99999999
Speed [r/min] 200 0 to maximum speed
Acceleration/deceleration
time constant [ms]
1000 0 to 50000
Repeat pattern
Fwd. rot. (CCW) to
rev. rot. (CW)
Fwd. rot. (CCW) to rev. rot. (CW)
Fwd. rot. (CCW) to fwd. rot. (CCW)
Rev. rot. (CW) to fwd. rot. (CCW)
Rev. rot. (CW) to rev. rot. (CW)
Dwell time [s] 2.0 0.1 to 50.0
Number of repeats [time] 1 1 to 9999
2) Operation method
Operation Screen control
Forward rotation start Click "Forward CCW".
Reverse rotation start Click "Reverse CW".
Pause Click "Pause".
Stop Click "Stop".
Forced stop Click "Forced Stop".
(c) Program operation
Positioning operation can be performed in two or more operation patterns combined, without using
the servo system controller. Use this operation with the forced stop reset. This operation may be
used independently of whether the servo is on or off and whether the servo system controller is
connected or not.
Exercise control on the program operation screen of MR Configurator2. For details, refer to Help of
MR Configurator2.
Operation Screen control
Start Click "Operation Start".
Pause Click "Pause".
Stop Click "Stop".
Forced stop Click "Forced Stop".
(d) Output signal (DO) forced output
Output signals can be switched on or off forcibly independently of the servo status. This function is
used for output signal wiring check, etc. Exercise control on the DO forced output screen of MR
Configurator2.

Table of Contents